11kv 630A Outdoor Air Break Switch
HomeHome > Products > MV Fuses > 11kv 630A Outdoor Air Break Switch
11kv 630A Outdoor Air Break Switch

11kv 630A Outdoor Air Break Switch

Package size per unit product 155.00cm * 66.00cm * 200.00cm Gross weight per unit product 2.200kg ++++ General FW1 type
Basic Info
Model NO. 11KV 630A
Specification FW1-12/24/36
Trademark haivol
Origin China
HS Code 3917310000
Production Capacity 10000
Packaging & Delivery
Package size per unit product 155.00cm * 66.00cm * 200.00cm Gross weight per unit product 2.200kg
Product Description
++++General

FW1 type Outdoor on load break switch (switch disconnector) contained in this list are destined to switch stub lines and ring main lines or transformers( It can be equipped with MV HRC fuse links as short circuit protection function) or for switching under on load conditions.
FW1 type switch comply with IEC/IEEE and DVE-recommendation standards. Especially comply with DIN VDE 0670 part 3 and IEC publication IEC-60265, IEC-129.

++++Service environment

  1. Air temperature: Maximum temperature: +75ºC; Minimum temperature:-45ºC
  1. Humidity: Monthly average humidity 95%; Daily average humidity 90% .
  1. Altitude above sea level: Maximum installation altitude: 2500m
  1. Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
  1. No frequent violent shake

++++ Features and benefits

  • Compact design
  • All steel parts either in stainless steel or hot-dip galvanized
  • Solid and stable base frame
  • Main contact with icing protection
  • Insulators available in porcelain or alternatively in silicone
  • Minimal sag for the line-connection thanks to the two fixed terminals
  • Completely maintenance antirust AL alloy -Arc chamber
  • Switching-off procedure without external arc
  • Short circuit making capacity under specific conditions possible
  • Fixing on the supporting structure either by clamping (free setting) or screwing (holes in the base frame)
  • Easy on-site installation and setting
  • High reliability: up to 1'000 cycles (depending on the making current)
  • All conducting parts either silver, nickel or tin-plated
  • Practically maintenance-free
  • ++++ Main technical specifications

  • Sheet 1

    No.ItemUnitData
    1Rated voltagekV122436
    2Rated frequencyHz50/60
    3Rated currentA200/400/630
    4Rated short circuit withstand current (1S)kA20
    5Rated peak withstand current (1S)kA50
    6Rated making currentkA31.5-50

    7

    Rated insulation level(HV)
    lightning impulse
    kV
    75/85125/145170/195
    Power frequency withstand4555/7575/100






    8
    Rated short circuit breaking capacity cos. Φ(0.7)
    Without maintenance of contacts
    ------------------------------





    - for active circuits
    20 breakings




    A
    630630400
    30 breakings400400300
    40 breakings300300250
    50 breakings250250170
    75 breakings170170160
    120 breakings110110110
    200 breakings656565
    280 breakings505050

    Sheet 2

    No.ItemUnitData
    1Rated voltagekV122436
    9For ring circuits breaking capacityA630400250
    10Rated breaking capacity of transformerA50
    11Rated breaking capacity of cable chargingA11
    12Rated breaking capacity of earthing faultA56

    Note:
    The FW1 type on load break switch (Switch disconnector) is equipped with stored energy released by fuse strike pins. The stored energy mechanism for the opening operation is released by fuse strike pins. The trip actuator is mounted on top of the fuse contact clip.
    The DIN type fuse is held in spring type contacts, secured by a tail lever. All the components are made of stainless steel, to prevent corrosion, have long live, and in the reset position. The trip lever is parked in an over-centre position.