IEC60282-2 11kv Composite Types of Dropout Fuse Cutout Link Switch
HomeHome > Products > MV Fuses > IEC60282-2 11kv Composite Types of Dropout Fuse Cutout Link Switch
IEC60282-2 11kv Composite Types of Dropout Fuse Cutout Link Switch

IEC60282-2 11kv Composite Types of Dropout Fuse Cutout Link Switch

Package size per unit product 40.00cm * 20.00cm * 10.00cm Gross weight per unit product 5.000kg Description Drop-out fus
Basic Info
Model NO. HRW-11/100
Shape Circle
Fusing Speed Fast K
Fusing Device Fuse Link
Standard IEC60282-2
Rated Current 100A, 200A, 400A
Rated Voltage 36kv
Creepage Distance 1200mm
Breaking Current 6300A
Transport Package Export Standard Package or as Client Requirement
Specification ISO9001: 2015
Trademark L&R
Origin Wenzhou, Zhejiang
HS Code 85351000
Production Capacity 20, 000PCS/Month
Packaging & Delivery
Package size per unit product 40.00cm * 20.00cm * 10.00cm Gross weight per unit product 5.000kg
Product Description
Description
Drop-out fused cut out and load Switching fuse cutout are of outdoor used high voltage protective device.To be connected with incoming feeder of distribution line it mainly protect transformer or lines from shortcircuit and overload, and on/off loading current.

Components
Drop-out fused cut out is composed of insulator supports and fuse tube. Static contacts is fixed on insulator support and moving contact is installed on two ends of fuse tube. Fuse tube is composed of:1. Inside arc estinguishing tube2. Outer phenolic compound paper tube or epoxy glass tubeLoad switching fuse cutout provides enforced elastic auxiliary contacts and arc-extinguishing enclosure for switching on/off loading current.
Operating Principle
1. When working normally, fuse link tightened the fuse tube to be close position.2. If system occur faults, big fault current melts fuse immediately and take place electric arc, which makesarc extinguishing tube being heated and explode a lot of gases. This will produce high pressure and blow off the arc along with tube.3. After fuselink melt moving contact has no tightened strength, mechanism is locked and fuse tube dropout.4. Cutout now is in open position. Operator shall use insulating Link Rod to pull the moving contact.

Main Parameter

TypeRated Voltage (kV)Rated Current (A)Breaking Current (A)Impulse Voltage Bil (BIL)Power Frequency withstand voltageLeakage Distance (mm)Weight (kg)Dimension (cm)
HRW-1212100630011040250640X36X11.5
HRW-121220010000110402506
TypeRated Voltage (kV)Rated Current (A)Breaking Current (A)Impulse Voltage Bil (BIL)Power Frequency withstand voltageLeakage Distance (mm)Weight (kg)Dimension (cm)
HRW-333310010000170708501290X40X17
HRW-3333200125001707085012

IEC60282-2 11kv Composite Types of Dropout Fuse Cutout Link Switch

IEC60282-2 11kv Composite Types of Dropout Fuse Cutout Link Switch

IEC60282-2 11kv Composite Types of Dropout Fuse Cutout Link Switch

IEC60282-2 11kv Composite Types of Dropout Fuse Cutout Link Switch